Description
PRODUCT DESCRIPTION
Endress Hauser Level Measurement Deltapilot, M FMB50
The Deltapilot M FMB50 is a hydrostatic pressure sensor used for hydrostatic pressure measurement in liquids and paste-like media in all areas of process engineering, process measuring technology, pharmaceuticals and the food industry; and for level, volume or mass measurements in liquids.
- Pressure sensor with the CONTITETM measuring cell
- Condensate proofed and long-term stable
- Communication via HART, PROFIBUS PA or FOUNDATION Fieldbus
BENEFITS:
- Very good reproducibility and long-term stability
- Turn down 100:1
- Hermetically sealed CONTITETM measuring cell:
- Condensate-resistant and climatic-proofed
- High reference accuracy: ±0.2 %, optionally ±0.1 %
- Minimum temperature effects
- End-to-end modularity for differential pressure, hydrostatics and pressure (Deltabar M – Deltapilot M – Cerabar M), e.g. replaceable display, universal electronics
- Easy commissioning without the need for an operating tool
- Easy and safe menu-guided operation
- On-site via display module
- Via 4 to 20 mA with HART
- Via PROFIBUS PA
- Via FOUNDATION Fieldbus
- Wide range of approvals (e.g. ATEX, FM, CSA, etc.) for international use
- Usage in drinking water: KTW, NSF
- Used for process pressure monitoring up to SIL2, certified to IEC 61508 Edition 2.0 and IEC 61511 by TÜV NORD
FEATURES AND SPECIFICATION:
CONTINUOUS / LIQUIDS:
- Measuring Principle: Hydrostatic
- Characteristic / Application:
- Pressure transmitter for hydrostatic level measurement, flush mounted CONTITE-sensor with metallic measuring diaphragm:
- Hermetically welded
- Absolute condensation tight
- Climate-resitant
- Long-term stable
- Lowest temperature influences
- Compact version
- Usage in liquids and paste media in all areas of process engineering, process measuring technology, pharmaceutical and the food industry
- Pressure transmitter for hydrostatic level measurement, flush mounted CONTITE-sensor with metallic measuring diaphragm:
- Supply Communication:
- 4…20mA HART: 11,5…45V DC, Ex ia: 11,5…30V DC
- PROFIBUS PA / FOUNDATION Fieldbus
- Accuracy: 0,2% optional 0,1%
- Long term stability: 0,05% of URL/year
- Ambient temperature: -40°C … 85°C (-40°F … 185°F)
- Process temperature: -10°C … 100°C (-14°F … 212°F)
- Process connection:
- Threads
- Flanges (EN, ANSI, JIS)
- Hygienic connections (flush mounted)
- Max. measurement distance: 100m (328ft) H2O
- Output: 4…20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
- Certificates / Approvals: ATEX; CSA; FM; IECEx; TIIS; NACE; SIL; 3A/ EHEDG approvals; inspection certificates; WHG/ Overfill prevention; CoC Certificate of Compliance
- Options:
- Separate housing
- Initial device settings
- Overvoltage protection
- Specialties:
- Modularity to differential pressure and process pressure devices (replacable display, universal electronics)
- Diagnostic functions
- Hermetically sealed Contite measuring cell (condensate-resistant and climatic-proofed)
- Application limits: If pressurized, usage of two pressure transmitters to measure the differential pressure (electronic dP); Observe ratio head pressure : hydrostatic pressure
- Process pressure absolute / max. overpressure limit: 40 bar (600 psi)
- Pressure measuring range: 100mbar…10bar (1.5psi…150psi)
- Main wetted parts: Alloy C276, 316L, optional coating AuPt, optional coating AuRh
PRESSURE:
- Measuring Principle: Hydrostatic
- Characteristic / Application:
- Pressure transmitter for hydrostatic level measurement, flush mounted CONTITE-sensor with metallic measuring diaphragm:
- Hermetically welded
- Absolute condensation tight
- Climate-resitant
- Long-term stable
- Lowest temperature influences
- Compact version
- Usage in liquids and paste media in all areas of process engineering, process measuring technology, pharmaceutical and the food industry
- Pressure transmitter for hydrostatic level measurement, flush mounted CONTITE-sensor with metallic measuring diaphragm:
- Supply Communication:
- 4…20mA HART: 11,5…45V DC, Ex ia: 11,5…30V DC
- PROFIBUS PA / FOUNDATION Fieldbus
- Specialties:
- Modularity to differential pressure and process pressure devices (replacable display, universal electronics)
- Diagnostic functions
- Hermetically sealed Contite measuring cell (condensate-resistant and climatic-proofed)
- Accuracy: 0,2% optional 0,1%
- Long term stability: 0,05% of URL/year
- Ambient temperature: -40°C … 85°C (-40°F … 185°F)
- Process temperature: -10°C … 100°C (-14°F … 212°F)
- Measuring range: 100mbar … 10 bar (1.5 psi…150 psi)
- Max. overpressure limit: 40 bar (600 psi)
- Process connection:
- Threads
- Flanges (EN, ANSI, JIS)
- Hygienic connections (flush mounted)
- Output: 4…20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
- Certificates / Approvals: ATEX; CSA; FM; IECEx; TIIS; NACE; SIL; 3A/ EHEDG approvals; drinking water approval; inspection certificates; WHG/ Overfill prevention; CoC Certificate of Compliance
- Options:
- Separate housing
- Initial device settings
- Overvoltage protection
- Application limits: If pressurized, usage of two pressure transmitters to measure the differential pressure (electronic dP); Observe ratio head pressure : hydrostatic pressure
Reviews