Endress Hauser Electronic Differential Pressure Deltabar S FMD78
The Deltabar FMD78 differential pressure transmitter with metal sensor uses two capillary diaphragm seals. Typically used in process and hygiene applications for continuous measurement of pressure differences in liquids, vapors, gases and dusts. The integrated HistoROM data module makes the management of process and device parameters easy. Designed according to IEC 61508 for use in SIL3 safety applications.
BENEFITS:
- Large variety of different process connections and membrane materials
- New TempC Membrane for diaphragm seals: Minimum temperature effects and short recovery times
- Highest safety due to gas tight feedthrough with capabilities up to SIL2/3, certified to IEC 61508
- Easy menu-guided commissioning via local display, 4 to 20 mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
- HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
- Cost savings with modular concept for easy replacement of sensor, display or electronics
- Seamless and independent system integration (HART/PA/FF)
FIELD OF APPLICATION:
For differential pressure, level, volume or mass measurement in liquids.
- Process connections: Threads, flanges, pancake and hygienic connections
- Process temperature: -70 up to +400°C (-94 to +752°F)
- Measuring ranges: 100mbar to +16bar (1.5 to 240psi);
- Accuracy: ±0.075%
- International explosion protection certificates, overfill prevention WHG, hygienic approvals, marine approvals, SIL
FEATURES AND SPECIFICATION:
CONTINUOUS / LIQUIDS:
- Measuring Principle: Differential pressure
- Characteristic / Application:
- Digital transmitter with metallic measuring measuring diaphragms, diaphragm seals and capillaries
- Modular transmitter
- Long term stability
- Enhanced safety via self diagnostic functions
- Secondary process barrier
- Supply Communication:
- 4…20 mA HART: 10,5…45V DC Ex ia: 10,5…30V DC
- PROFIBUS PA / FOUNDATION Fieldbus: 9…32V DC
- Accuracy: 0,075% + influence of diaphragm seal
- Long term stability: 0,05% of URL/year
- Ambient temperature: -40°C … 85°C (-40°F … 185°F)
- Process temperature: -40°C…400°C (-40°F…662°F)
- Process pressure absolute / max. overpressure limit: 160bar (2400 psi)
- Pressure measuring range: 100mbar…40bar (1.5psi…600psi)
- Main wetted parts: Alloy C276; 316L; Monel; Tantalum
- Process connection: Diaphragm seal (Pancakes, threads); Flanges (DIN, ANSI); Tri-Clamp ISO2852; Hygienic connections
- Max. measurement distance: 400m (1312ft) H2O
- Output: 4…20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
- Certificates / Approvals: ATEX; FM; CSA; NEPSI; ICECEx; SIL; NACE; GL marine; WHG/ Overfill prevention; EN10204-3.1; 3A
- Options:
- HistoROM/M-Dat
- 4-line digital display
- SS- or Aluminum housing
- Separate housing
- Application limits: Measuring cell: Metal welded
PRESSURE:
- Measuring Principle: Differential pressure
- Characteristic / Application:
- Digital transmitter with metallic measuring diaphragms, diaphragm seals and capillaries
- Modular transmitter
- Long term stability
- Enhanced safety via self diagnostic functions
- Secondary process barrier
- Supply Communication:
- 4…20 mA HART: 10,5…45V DC Ex ia: 10,5…30V DC
- PROFIBUS PA / FOUNDATION Fieldbus: 9…32V DC
- Accuracy: 0,075% + influence of diaphragm seal
- Long term stability: 0,05% of URL/year; 0,125% of URL/5 years
- Ambient temperature: -40°C … 85°C (-40°F … 185°F)
- Process temperature: -70°C…400°C (-94°F…752°F)
- Measuring range: 100mbar…40bar (40inH2O…600psi)
- Max. overpressure limit: 160 bar (2400 psi)
- Process connection: Diaphragm seal (Pancake, threads); Flanges (DIN, ANSI); Hygienic connections; Tri-Clamp ISO2852
- Output: 4…20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
- Certificates / Approvals: ATEX; FM; CSA; NEPSI; ICECEx; WGH/ Overfill prevention; SIL; NACE; GL marine; EN10204-3.1; 3A, FDA
- Options:
- HistoROM/M-Dat
- 4-line digital display
- SS- or Aluminum housing
- Separate housing
- Specialties: Diagnostic functions